Skip Navigation
Skip to contents

Intest Res : Intestinal Research

IMPACT FACTOR

Articles

Page Path
HOME > Intest Res > Volume 24(1); 2026 > Article
Original Article
Tumor
Does the size of the cold snare affect the outcome of cold snare polypectomy in the colon? A KASID prospective multicenter study
Seongwoo Choi1,*orcid, Jaeyoung Chun2,*orcid, Geunhyuk Choi1orcid, Yoojin Lee3orcid, Taegeun Gweon4orcid, Yunho Jung1orcid
Intestinal Research 2026;24(1):76-83.
DOI: https://doi.org/10.5217/ir.2025.00189
Published online: January 28, 2026

1Department of Internal Medicine, Soonchunhyang University College of Medicine, Asan, Korea

2Department of Internal Medicine, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, Korea

3Department of Internal Medicine, Keimyung University School of Medicine, Daegu, Korea

4Department of Internal Medicine, Bucheon St. Mary’s Hospital, College of Medicine, The Catholic University, Bucheon, Korea

Correspondence to Yunho Jung, Division of Gastroenterology, Department of Internal Medicine, Soonchunhyang University College of Medicine, 22 Soonchunhyang-ro, Asan 31538, Korea. E-mail: yunho7575@gmail.com
*These authors contributed equally to this study as first authors.
• Received: August 23, 2025   • Revised: October 18, 2025   • Accepted: October 30, 2025

© 2025 Korean Association for the Study of Intestinal Diseases.

This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.

prev next
  • 564 Views
  • 19 Download
  • Background/Aims
    Cold snare polypectomy (CSP) is recommended for colorectal polyps <10 mm; however, the impact of snare size on clinical outcomes remains unclear. This study evaluated the efficacy and safety of 10-mm and 15-mm snares for CSP of small colorectal polyps.
  • Methods
    In this prospective multicenter study, patients with 4–10 mm non-pedunculated polyps underwent CSP with either a 10-mm or 15-mm snare. Both snares had identical wire thickness and hexagonal loop design. The primary outcome was histological complete resection rate (CRR). Secondary outcomes included adverse events and technical parameters.
  • Results
    In total, 182 patients were enrolled (10-mm group: n = 92; 15-mm group: n = 90). Baseline characteristics, including age, sex, polyp size, morphology, location, and pathology, were comparable between groups. Histological CRRs were 90.2% in the 10-mm group and 91.1% in the 15-mm group (P= 0.483). No significant differences were observed in the presence of submucosal tissue within specimens (P= 0.523), iatrogenic ulcer size (P= 0.532), hematoma occurrence (P= 0.391), or intraprocedural bleeding requiring hemostasis (6.5% vs. 5.6%; P= 0.974). No cases of delayed bleeding or perforation were reported. Logistic regression analysis identified iatrogenic ulcer size > 8 mm as an independent predictor of complete resection (odds ratio, 3.89; 95% confidence interval, 1.15–13.21; P= 0.029); snare size was not significantly associated with CRR (P= 0.519).
  • Conclusions
    CSP using either a 10-mm or a 15-mm snare for 4–10 mm non-pedunculated colorectal polyps showed no significant difference in complete resection or safety outcomes within this size range. (Clinical Research Information Service [CRIS], KCT0005031)
Colorectal polypectomy remains a cornerstone in the prevention and treatment of colorectal cancer, with evidence demonstrating its ability to reduce incidence by up to 53% in individuals who undergo the procedure compared with those who do not [1]. The optimal technique for polypectomy, however, requires careful consideration of multiple factors, including the histological features, size, and location of the polyp. Central to this decision is the goal of achieving en bloc or complete resection to minimize local recurrence while ensuring procedural safety and reducing complications.
Among emerging techniques, cold snare polypectomy (CSP) has gained considerable attention for the resection of diminutive and small polyps. CSP is generally performed using a 10–15 mm mini-oval snare or a dedicated cold snare, particularly for polyps measuring less than 10 mm. After gentle air aspiration, the polyp is ensnared and mechanically transected without electrocautery, thus eliminating the need for submucosal injection. This approach is both safe and effective [2-4]. A meta-analysis of diminutive polyps (1–5 mm) demonstrated that the incomplete resection rate was significantly lower with CSP (4.4%; 95% confidence interval [CI], 2.9–6.1) than with forceps biopsy (9.9%; 95% CI, 7.1–13.0), leading to the recommendation of CSP over forceps resection for this size range [5]. Furthermore, comparative analyses of CSP and hot snare polypectomy (HSP), which uses electrocautery, revealed no significant differences in complete resection or tissue retrieval rates for polyps <1 cm. However, CSP was associated with significantly shorter procedure times [6,7]. Based on these findings, recent international guidelines recommend CSP as the preferred technique for resecting polyps <10 mm [4,8].
Despite these advantages, one technical factor that remains underexplored is the size of the snare used during CSP. In routine clinical practice, endoscopists often use snares of different sizes interchangeably, depending on lesion characteristics and procedural convenience. Larger snares may facilitate improved capture and stability for certain lesions but may also increase bleeding risk or reduce precision for smaller targets. Conversely, smaller snares may present technical limitations when used for polyps at the upper end of the size range. At present, evidence is limited regarding whether snare size influences clinical outcomes—particularly resection completeness, bleeding risk, or overall safety—for polyps measuring 4–10 mm, the most frequently encountered size range in routine colonoscopy.
Therefore, this prospective study aimed to compare the efficacy and safety of CSP using 10-mm versus 15-mm snares for polyps measuring 4–10 mm by evaluating complete resection rates (CRRs) and the incidence of immediate and delayed bleeding, with the goal of informing best practices and providing evidence-based guidance for optimal snare selection in CSP.
1. Patients
This prospective, randomized study was conducted at 4 tertiary hospitals between March 2020 and March 2021. Eligible patients were those with non-pedunculated colorectal polyps measuring 4–10 mm who underwent CSP. Exclusion criteria included polyps <3 mm or >11 mm, use of antiplatelet or anticoagulant agents within 5 days before the procedure, and a diagnosis of inflammatory bowel disease. In total, 220 patients were enrolled and randomly assigned to undergo CSP with either a 10-mm snare (n=110) or a 15-mm snare (n=110). After histopathological evaluation, 38 lesions with non-neoplastic histology were excluded, leaving 182 polyps for the final analysis (Fig. 1).
2. Polypectomy Protocol
Prior to polypectomy, information regarding polyp size, location, and morphology was documented. Polyp size was measured using biopsy forceps (closed diameter, 2.4 mm; fully opened, approximately 7 mm). During resection, the polyp was positioned at the 5–7 o’clock orientation and resected with an adequate margin to ensure complete removal. No submucosal injection was performed. If multiple polyps were detected, the same snare was used for all resections.
Cold snaring was performed using one of two dedicated snares (10 mm or 15 mm; SnareMaster Plus, Olympus, Tokyo, Japan) with identical wire thickness and a hexagonal loop design. These snares are specifically designed for cold polypectomy, featuring a thin yet rigid wire that enables sharp mechanical transection without electrocautery, thereby minimizing thermal injury. The hexagonal loop facilitates stable lesion capture, reduces slippage risk, and supports en bloc resection with adequate margins (Table 1, Figs. 2 and 3).
Resected polyps were aspirated through the colonoscope’s working channel into a polyp trap and retrieved. The resection site was irrigated with water, and luminal distention was performed to assess iatrogenic ulcer size, resection completeness, and bleeding status. The size of iatrogenic ulcers was measured using biopsy forceps (closed diameter, approximately 2.5 mm; fully opened, approximately 7 mm) to ensure standardized assessment. Bleeding was evaluated after 1 min; if grade ≥ 3 bleeding persisted, endoscopic hemostasis was performed [9]. All resected specimens were individually submitted to experienced gastrointestinal pathologists for histological evaluation of complete resection.
3. Study Outcomes
The primary outcome was the histological CRR. Secondary outcomes included technical aspects of CSP (e.g., retrieval rate and fly-away rate), histological characteristics of resected specimens (pathologic diagnosis and depth of resection), and adverse events (e.g., bleeding or perforation).
4. Ethical Considerations and Statistical Analysis
This study was approved by the institutional ethics committee and is registered under KCT0005031 at the Clinical Research Information Service (https://cris.nih.go.kr/cris/en/index.jsp). Informed consent was obtained from all patients before enrollment. The study was conducted in accordance with the Declaration of Helsinki and was approved by the institutional review boards of the participating hospitals (IRB No. SCHCA 2019-08-044-004).
The null hypothesis was that the difference in CRR between the 10-mm and 15-mm snare groups would be 9.5%. Based on a previous study, the CRR for the 10-mm snare group was assumed to be 88%, whereas the CRR for the 15-mm snare group was set at 97.5% [2,10]. With a two-sided α of 0.05 and 80% power, the minimum required sample size was calculated as 207 patients. After incorporation of an anticipated 5% dropout rate, the final required sample size was 218 patients. All statistical analyses were performed using SPSS version 24.0 (IBM Corp., Armonk, NY, USA). Categorical variables were compared between groups using either the chi-square test or Fisher exact test, as appropriate.
1. Patient and Polyp Characteristics
In total, 182 patients were included in the study: 92 in the 10-mm CSP group and 90 in the 15-mm group. The mean ages were 61.5 ± 10.7 years and 63.6 ± 9.3 years, and the mean polyp sizes were 6.2 ± 1.4 mm and 6.0 ± 1.2 mm, respectively, with no significant differences between the groups (P=0.278 for age; P=0.101 for polyp size). Baseline characteristics, including sex distribution, indication for colonoscopy, bowel preparation quality, use of antithrombotic agents, and other polyp features, were also comparable between groups. Sessile morphology was the most common finding (77.2% vs. 72.2%), lesions were slightly more prevalent in the left colon (56.5% vs. 51.1%), and adenomas represented the predominant pathology (81.5% vs. 86.7%) (Table 2).
2. Comparison of Procedural and Clinical Outcomes
For the primary outcome of histological complete resection, the overall CRR was 90.7% (90.2% in the 10-mm group vs. 91.1% in the 15-mm group; P=0.483) (Table 3). No significant differences were observed between groups in specimen depth containing submucosal tissue (P=0.523), iatrogenic ulcer size (P=0.532), or hematoma occurrence (P=0.391). No cases of delayed bleeding or perforation were reported in either group. Intraprocedural bleeding that resolved spontaneously within 1 minute occurred in 15.2% and 17.8% of patients, whereas bleeding requiring endoscopic hemostasis occurred in 6.5% and 5.6% of patients in the 10-mm and 15-mm groups, respectively (P=0.974).
3. Factors Associated with Complete Resection
Of the 182 lesions analyzed, complete resection was achieved in 165 cases (90.7%); 17 cases (9.3%) were classified as incomplete resections. In univariate analysis, iatrogenic ulcer size was significantly associated with complete resection (P=0.046), and incomplete resection occurred less frequently when ulcer size was >8 mm (Table 4). Logistic regression analysis confirmed that an iatrogenic ulcer size >8 mm was independently associated with a higher CRR (odds ratio, 3.89; 95% CI, 1.15–13.21; P=0.029) (Table 5). No significant associations were identified between complete resection and snare size (P=0.519), polyp size (P=0.578), polyp morphology (P=0.257), pathology (P=0.110), or depth of excision (P=0.587) (Table 4).
Several guidelines, including those from the European Society of Gastrointestinal Endoscopy [4] and the U.S. Multi-Society Task Force [8], recommend CSP as the preferred method for removing colorectal polyps smaller than 1 cm. CSP has since become widely adopted in routine clinical practice, and various snare sizes are available. Despite its widespread use, limited data exist on the impact of snare size on clinical outcomes. In real-world practice, when colon polypectomy techniques such as endoscopic mucosal resection are performed with a relatively large snare (e.g., 15 or 20 mm), endoscopists often continue to use the same device to remove additional small polyps rather than switching to a smaller snare. This pragmatic approach may raise concerns, such as an increased risk of bleeding or difficulty in precisely capturing smaller lesions. Conversely, some clinicians argue that a larger snare may provide more stable capture and facilitate en bloc resection. These unresolved considerations highlight the need for a systematic comparison of snare sizes in CSP; however, direct comparative studies remain scarce.
In this prospective study, we compared the efficacy and safety of 10-mm and 15-mm cold snares for the removal of polyps measuring 4–10 mm, which represent the most commonly encountered lesions in clinical practice. Histological CRRs did not significantly differ between the 10-mm and 15-mm snare groups (90.2% vs. 91.1%), and there were no differences in complications such as delayed bleeding or perforation. The incidence of fly-away polyps was low (4.3% vs. 6.7%), retrieval rates were 100% in both groups, and other technical outcomes (e.g., specimen depth, ulcer size, and hematoma occurrence) also were not significantly different. These findings suggest that both snare sizes are equally effective and safe for the removal of polyps ≤10 mm.
Our results differed from those of a Japanese retrospective study by Noda et al. [11], the first to evaluate CSP outcomes according to snare size, which compared a short (13 mm) and a long (27 mm) snare for polyps ≤10 mm. That study revealed a significantly higher histological CRR with the short snare than with the long snare (61.6% vs. 44.9%; P<0.05); there was no difference in complication rates. The authors suggested that shorter snares may allow more secure capture of surrounding normal mucosa, thereby providing a wider safety margin and reducing the likelihood of residual tissue at the resection margin. In contrast, our prospective study demonstrated no significant difference in histological CRRs between 10-mm and 15-mm snares; both groups achieved excellent retrieval rates and low rates of fly-away polyps. The discrepancy between our findings and the previous study may be attributable to differences in study design (prospective vs. retrospective), the magnitude of snare size difference (13 mm vs. 27 mm in the previous study compared with 10 mm vs. 15 mm in our study), snare shape (hexagonal vs. oval), wire characteristics, and operator experience. The generally higher CRRs reported in more recent studies, ranging from 90% to 98% [2,6,10,12,13], are consistent with our results but substantially higher than those in the earlier study. This difference may reflect the timing of the earlier study, conducted before CSP was widely adopted (when operator proficiency was likely lower), as well as the potential negative impact of using a relatively large snare on CRR.
In our study, iatrogenic ulcer size was the only factor significantly associated with CRR, suggesting that securing an adequate resection margin is more critical for achieving complete resection than the choice between 10-mm and 15-mm snares. Our findings are consistent with prior evidence underscoring the importance of margin capture for histological completeness. A previous study reported that extended CSP with a circumferential margin ≥ 1 mm significantly increased the R0 resection rate to nearly 98% without raising the risk of delayed bleeding or perforation [13]. Taken together, these results highlight that margin capture, rather than snare size itself, is the key determinant of complete resection. Nonetheless, as observed in the previous study [11], the use of an excessively large snare (e.g., 27 mm) for small polyps may hinder proper capture and potentially reduce CRR, an issue that warrants further investigation in future research.
The present study also confirmed the procedural safety of CSP in both snare groups. There were no cases of perforation or delayed bleeding, and the rate of intraprocedural bleeding requiring hemostasis was comparable to or slightly lower than that reported in previous studies (approximately 6.6%–20%) [14-17]. Specifically, intraprocedural bleeding requiring hemostatic intervention occurred in 6.5% of patients in the 10-mm group and 5.6% in the 15-mm group, indicating a comparable and favorable safety profile regardless of snare size. We also hypothesized that a larger snare size might achieve greater resection depth. However, the proportions of specimens containing the submucosal layer were 16.3% in the 10-mm snare group and 17.8% in the 15-mm snare group, with no statistically significant difference (P=0.523). A previous randomized controlled trial comparing HSP and CSP reported that approximately 24% of CSP specimens included the submucosal layer, which is slightly higher than in the present study but not substantially different [18]. Notably, that study compared resection techniques, rather than snare sizes, and demonstrated that CSP generally yields a shallower resection depth than HSP.
This study had several limitations. First, the endoscopists were not blinded to the type of snare being used, which may have introduced bias. However, a randomized lottery method was utilized to allocate snare type when a polyp was detected, thereby minimizing operator selection bias. Second, the size difference between the 2 snares (10 mm vs. 15 mm) may not represent a substantial contrast compared with a previous study that examined more extreme differences [11]. We specifically selected these sizes because they are the most commonly used in clinical practice and, importantly, were available from the same manufacturer with identical wire thickness and shape. This design allowed us to isolate snare size as the primary variable while controlling for other device-related factors. Third, because this was a multicenter study, variability in operator experience and procedural techniques across centers could have influenced the outcomes.
Despite these limitations, to the best of our knowledge, this was the first prospective, multicenter study to compare CSP outcomes according to snare size, providing clinically relevant evidence to inform everyday endoscopic practice. These findings support the use of either 10-mm or 15-mm snares for CSP of small colorectal polyps, with comparable efficacy and safety profiles. Given the similar performance observed within this range, snare selection may reasonably be guided by operator preference and procedural context. Future studies should investigate whether extremely large snares or other device characteristics, such as snare shape or wire properties, influence resection quality, particularly in specific lesion types or challenging anatomical locations.
In conclusion, CSP using either a 10-mm or a 15-mm snare for non-pedunculated colorectal polyps measuring 4–10 mm demonstrated comparable CRRs and similar safety profiles, with no significant differences in adverse events such as bleeding. Within this commonly used size range, snare selection may therefore be based on operator preference and procedural considerations, rather than expected differences in clinical efficacy.

Funding Source

This work was supported by the Soonchunhyang University Research Fund.

Conflict of Interest

Lee Y is an editorial board member of the journal but was not involved in the peer reviewer selection, evaluation, or decision process of this article. No other potential conflicts of interest relevant to this article were reported.

Data Availability Statement

Data analyzed in this study are available from the corresponding author upon reasonable request.

Author Contributions

Conceptualization: Chun J, Lee Y, Gweon T, Jung Y. Data curation: Chun J, Gweon T, Jung Y. Formal analysis: Chun J, Jung Y. Investigation: Lee Y, Gweon T. Methodology: Chun J, Jung Y. Project administration: Jung Y. Supervision: Jung Y. Writing – original draft: Choi S. Writing – review & editing: all authors. Approval of final manuscript: all authors.

Fig. 1.
Study design and population.
ir-2025-00189f1.jpg
Fig. 2.
Cold snare polypectomy with a 10-mm dedicated snare. (A) A 6-mm flat elevated polyp in the descending colon. (B) Positioning of the snare around the lesion. (C) Transection with an adequate margin. (D) Post-resection mucosal defect.
ir-2025-00189f2.jpg
Fig. 3.
Cold snare polypectomy with a 15-mm dedicated snare. (A) A 7-mm sessile polyp in the sigmoid colon. (B) Positioning of the snare around the lesion. (C) Transection with an adequate margin. (D) Post-resection mucosal defect.
ir-2025-00189f3.jpg
ir-2025-00189f4.jpg
Table 1.
Summary of Snare Characteristics
Snare (model name)
Olympus SD-400U-10 Olympus SD-400U-15
Shape of the snare loop Hexagon Hexagon
Indication for use Hot cut & Cold cut Hot cut & Cold cut
Maximum insertion portion diameter (mm) 0.26 0.26
Rotation of the snare loop No No
Working length (cm) 230 230
Loop width (mm) 10 15
Diameter of the snare loop wire (mm) 0.3 0.3
Sheath material Teflon Teflon
Table 2.
Baseline Characteristics
Variable 10-mm size cold snare (n = 92) 15-mm size cold snare (n = 90) P-value
Age (yr), mean ± SD 61.5 ± 10.7 63.6 ± 9.3 0.278
Male sex 61 (66.3) 63 (70.0) 0.426
Indication 0.454
 Screening 48 (52.1) 45 (50.0)
 Surveillance 44 (47.9) 45 (50.0)
Preparation quality (good) 87 (94.6) 81 (90.0) 0.313
Antithrombotic 0.561
 Antiplatelet 3 (3.3) 0
 Anticoagulant 7 (7.6) 5 (5.6)
Polyp size (mm), mean ± SD 6.2 ± 1.4 6.0 ± 1.2 0.101
 4–6 mm 54 (58.7) 62 (68.9)
 7–10 mm 38 (41.3) 28 (31.1)
Polyp type 0.654
 Flat 21 (22.8) 25 (27.8)
 Sessile 71 (77.2) 65 (72.2)
Polyp location 0.393
 Right colon 40 (43.5) 44 (48.9)
 Left colon 52 (56.5) 46 (51.1)
Pathology 0.239
 Adenoma 75 (81.5) 78 (86.7)
 SSA/P 17 (18.5) 12 (13.3)

Values are presented as number (%) unless otherwise indicated.

SD, standard deviation; SSA/P, sessile serrated adenoma/polyp.

Table 3.
Comparison of Technical Factors and Adverse Events
Variable 10-mm size cold snare (n = 92) 15-mm size cold snare (n = 90) P-value
Histological complete resection 83 (90.2) 82 (91.1) 0.483
Depth of specimens 0.523
 Muscularis mucosa 42 (45.7) 39 (43.3)
 Submucosa 15 (16.3) 16 (17.8)
Iatrogenic ulcer size 0.532
 ≤ 8 mm 68 (73.9) 66 (73.3)
 > 8 mm 24 (26.1) 24 (26.7)
Fly away 4 (4.3) 6 (6.7) 0.360
Retrieval rate 92 (100) 90 (100) -
Hematoma 11 (12.0) 13 (14.4) 0.391
Intraprocedural bleeding 0.974
 Spontaneous hemostasis after 1 min 14 (15.2) 16 (17.8)
 Requiring endoscopic hemostasis 6 (6.5) 5 (5.6)
Adverse events -
 Delayed bleeding 0 0
 Perforation 0 0

Values are presented as number (%).

Table 4.
Comparison of Complete and Incomplete Resection between the 2 Groups
Variable Category Complete resection Incomplete resection P-value
Snare size 10 mm 90.2 (83/92) 9.8 (9/92) 0.519
15 mm 91.1 (82/90) 8.9 (8/90)
Polyp size 4–6 mm 90.5 (105/116) 9.5 (11/116) 0.578
7–10 mm 90.9 (60/66) 9.1 (6/66)
Polyp shape Flat 84.8 (39/46) 15.2 (7/46) 0.257
Sessile 92.6 (126/136) 7.4 (10/136)
Polyp location Right colon 92.9 (78/84) 7.1 (6/84) 0.544
Left colon 88.8 (87/98) 11.2 (11/98)
Pathology Adenoma 92.2 (141/153) 7.8 (12/153) 0.110
SSL 82.8 (24/29) 17.2 (5/29)
Depth of specimens MM 90.5 (67/74) 9.5 (7/74) 0.587
SM 90.0 (27/30) 10.0 (3/30)
Iatrogenic ulcer size ≤ 8 mm 88.1 (118/134) 11.9 (16/134) 0.046
> 8 mm 97.9 (47/48) 2.1 (1/48)

Values are presented as % (number/number).

SSL, sessile serrated lesion; MM, muscularis mucosa; SM, submucosa.

Table 5.
Logistic Regression Analysis of Complete Resection Rate
Variable Category OR (95% CI) P-value
Snare size 10 mm (reference)
15 mm 1.09 (0.38–3.16) 0.868
Polyp size 4–6 mm (reference)
7–10 mm 1.05 (0.13–8.26) 0.962
Pathology (%) Adenoma (reference)
SSL 1.68 (0.45–6.26) 0.443
Iatrogenic ulcer size ≤ 8 mm (reference)
> 8 mm 3.89 (1.15–13.21) 0.029

OR, odds ratio; CI, confidence interval; SSL, sessile serrated lesion.

  • 1. Zauber AG, Winawer SJ, O’Brien MJ, et al. Colonoscopic polypectomy and long-term prevention of colorectal-cancer deaths. N Engl J Med 2012;366:687–696.ArticlePubMedPMC
  • 2. Moond V, Loganathan P, Malik S, et al. Cold snare polypectomy versus cold endoscopic mucosal resection for small colorectal polyps: a meta-analysis of randomized controlled trials. Clin Endosc 2024;57:747–758.ArticlePubMedPMCPDF
  • 3. Niu C, Bapaye J, Zhang J, et al. Systematic review and meta-analysis of cold snare polypectomy and hot snare polypectomy for colorectal polyps. J Gastroenterol Hepatol 2023;38:1458–1467.ArticlePubMed
  • 4. Ferlitsch M, Hassan C, Bisschops R, et al. Colorectal polypectomy and endoscopic mucosal resection: European Society of Gastrointestinal Endoscopy (ESGE) Guideline-Update 2024. Endoscopy 2024;56:516–545.ArticlePubMed
  • 5. Djinbachian R, Iratni R, Durand M, Marques P, von Renteln D. Rates of incomplete resection of 1- to 20-mm colorectal polyps: a systematic review and meta-analysis. Gastroenterology 2020;159:904–914.e12.ArticlePubMed
  • 6. Shinozaki S, Kobayashi Y, Hayashi Y, Sakamoto H, Lefor AK, Yamamoto H. Efficacy and safety of cold versus hot snare polypectomy for resecting small colorectal polyps: systematic review and meta-analysis. Dig Endosc 2018;30:592–599.ArticlePubMedPDF
  • 7. Kawamura T, Takeuchi Y, Yokota I, Takagaki N. Indications for cold polypectomy stratified by the colorectal polyp size: a systematic review and meta-analysis. J Anus Rectum Colon 2020;4:67–78.ArticlePubMedPMC
  • 8. Kaltenbach T, Anderson JC, Burke CA, et al. Endoscopic removal of colorectal lesions-recommendations by the US Multi-Society Task Force on Colorectal Cancer. Gastroenterology 2020;158:1095–1129.ArticlePubMed
  • 9. Kim HS, Kim TI, Kim WH, et al. Risk factors for immediate postpolypectomy bleeding of the colon: a multicenter study. Am J Gastroenterol 2006;101:1333–1341.ArticlePubMed
  • 10. Pedersen IB, Rawa-Golebiewska A, Calderwood AH, et al. Complete polyp resection with cold snare versus hot snare polypectomy for polyps of 4-9 mm: a randomized controlled trial. Endoscopy 2022;54:961–969.ArticlePubMed
  • 11. Noda H, Ogasawara N, Sugiyama T, et al. The influence of snare size on the utility and safety of cold snare polypectomy for the removal of colonic polyps in Japanese patients. J Clin Med Res 2016;8:662–666.ArticlePubMedPMC
  • 12. Kim MJ, Na SY, Kim JS, et al. Cold snare polypectomy versus cold endoscopic mucosal resection for small colorectal polyps: a multicenter randomized controlled trial. Surg Endosc 2023;37:3789–3795.ArticlePubMedPDF
  • 13. Abe Y, Nabeta H, Koyanagi R, et al. Extended cold snare polypectomy for small colorectal polyps increases the R0 resection rate. Endosc Int Open 2018;6:E254–E258.ArticlePubMedPMC
  • 14. Oh SJ, Jung Y, Hwangbo Y, Cho YS, Chung IK, Lee CK. Prediction of immediate bleeding after cold snare polypectomy: a prospective observational study. Medicine (Baltimore) 2024;103:e39597.ArticlePubMedPMC
  • 15. Kawamura T, Takeuchi Y, Asai S, et al. A comparison of the resection rate for cold and hot snare polypectomy for 4-9 mm colorectal polyps: a multicentre randomised controlled trial (CRESCENT study). Gut 2018;67:1950–1957.ArticlePubMed
  • 16. Jegadeesan R, Aziz M, Desai M, et al. Hot snare vs. cold snare polypectomy for endoscopic removal of 4 - 10 mm colorectal polyps during colonoscopy: a systematic review and meta-analysis of randomized controlled studies. Endosc Int Open 2019;7:E708–E716.ArticlePubMedPMC
  • 17. Horiuchi A, Hosoi K, Kajiyama M, Tanaka N, Sano K, Graham DY. Prospective, randomized comparison of 2 methods of cold snare polypectomy for small colorectal polyps. Gastrointest Endosc 2015;82:686–692.ArticlePubMed
  • 18. Suzuki S, Gotoda T, Kusano C, et al. Width and depth of resection for small colorectal polyps: hot versus cold snare polypectomy. Gastrointest Endosc 2018;87:1095–1103.ArticlePubMed

Figure & Data

REFERENCES

    Citations

    Citations to this article as recorded by  

      • PubReader PubReader
      • ePub LinkePub Link
      • Cite
        CITE
        export Copy Download
        Close
        Download Citation
        Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

        Format:
        • RIS — For EndNote, ProCite, RefWorks, and most other reference management software
        • BibTeX — For JabRef, BibDesk, and other BibTeX-specific software
        Include:
        • Citation for the content below
        Does the size of the cold snare affect the outcome of cold snare polypectomy in the colon? A KASID prospective multicenter study
        Intest Res. 2026;24(1):76-83.   Published online January 28, 2026
        Close
      • XML DownloadXML Download
      Figure
      • 0
      • 1
      • 2
      • 3
      Does the size of the cold snare affect the outcome of cold snare polypectomy in the colon? A KASID prospective multicenter study
      Image Image Image Image
      Fig. 1. Study design and population.
      Fig. 2. Cold snare polypectomy with a 10-mm dedicated snare. (A) A 6-mm flat elevated polyp in the descending colon. (B) Positioning of the snare around the lesion. (C) Transection with an adequate margin. (D) Post-resection mucosal defect.
      Fig. 3. Cold snare polypectomy with a 15-mm dedicated snare. (A) A 7-mm sessile polyp in the sigmoid colon. (B) Positioning of the snare around the lesion. (C) Transection with an adequate margin. (D) Post-resection mucosal defect.
      Graphical abstract
      Does the size of the cold snare affect the outcome of cold snare polypectomy in the colon? A KASID prospective multicenter study
      Snare (model name)
      Olympus SD-400U-10 Olympus SD-400U-15
      Shape of the snare loop Hexagon Hexagon
      Indication for use Hot cut & Cold cut Hot cut & Cold cut
      Maximum insertion portion diameter (mm) 0.26 0.26
      Rotation of the snare loop No No
      Working length (cm) 230 230
      Loop width (mm) 10 15
      Diameter of the snare loop wire (mm) 0.3 0.3
      Sheath material Teflon Teflon
      Variable 10-mm size cold snare (n = 92) 15-mm size cold snare (n = 90) P-value
      Age (yr), mean ± SD 61.5 ± 10.7 63.6 ± 9.3 0.278
      Male sex 61 (66.3) 63 (70.0) 0.426
      Indication 0.454
       Screening 48 (52.1) 45 (50.0)
       Surveillance 44 (47.9) 45 (50.0)
      Preparation quality (good) 87 (94.6) 81 (90.0) 0.313
      Antithrombotic 0.561
       Antiplatelet 3 (3.3) 0
       Anticoagulant 7 (7.6) 5 (5.6)
      Polyp size (mm), mean ± SD 6.2 ± 1.4 6.0 ± 1.2 0.101
       4–6 mm 54 (58.7) 62 (68.9)
       7–10 mm 38 (41.3) 28 (31.1)
      Polyp type 0.654
       Flat 21 (22.8) 25 (27.8)
       Sessile 71 (77.2) 65 (72.2)
      Polyp location 0.393
       Right colon 40 (43.5) 44 (48.9)
       Left colon 52 (56.5) 46 (51.1)
      Pathology 0.239
       Adenoma 75 (81.5) 78 (86.7)
       SSA/P 17 (18.5) 12 (13.3)
      Variable 10-mm size cold snare (n = 92) 15-mm size cold snare (n = 90) P-value
      Histological complete resection 83 (90.2) 82 (91.1) 0.483
      Depth of specimens 0.523
       Muscularis mucosa 42 (45.7) 39 (43.3)
       Submucosa 15 (16.3) 16 (17.8)
      Iatrogenic ulcer size 0.532
       ≤ 8 mm 68 (73.9) 66 (73.3)
       > 8 mm 24 (26.1) 24 (26.7)
      Fly away 4 (4.3) 6 (6.7) 0.360
      Retrieval rate 92 (100) 90 (100) -
      Hematoma 11 (12.0) 13 (14.4) 0.391
      Intraprocedural bleeding 0.974
       Spontaneous hemostasis after 1 min 14 (15.2) 16 (17.8)
       Requiring endoscopic hemostasis 6 (6.5) 5 (5.6)
      Adverse events -
       Delayed bleeding 0 0
       Perforation 0 0
      Variable Category Complete resection Incomplete resection P-value
      Snare size 10 mm 90.2 (83/92) 9.8 (9/92) 0.519
      15 mm 91.1 (82/90) 8.9 (8/90)
      Polyp size 4–6 mm 90.5 (105/116) 9.5 (11/116) 0.578
      7–10 mm 90.9 (60/66) 9.1 (6/66)
      Polyp shape Flat 84.8 (39/46) 15.2 (7/46) 0.257
      Sessile 92.6 (126/136) 7.4 (10/136)
      Polyp location Right colon 92.9 (78/84) 7.1 (6/84) 0.544
      Left colon 88.8 (87/98) 11.2 (11/98)
      Pathology Adenoma 92.2 (141/153) 7.8 (12/153) 0.110
      SSL 82.8 (24/29) 17.2 (5/29)
      Depth of specimens MM 90.5 (67/74) 9.5 (7/74) 0.587
      SM 90.0 (27/30) 10.0 (3/30)
      Iatrogenic ulcer size ≤ 8 mm 88.1 (118/134) 11.9 (16/134) 0.046
      > 8 mm 97.9 (47/48) 2.1 (1/48)
      Variable Category OR (95% CI) P-value
      Snare size 10 mm (reference)
      15 mm 1.09 (0.38–3.16) 0.868
      Polyp size 4–6 mm (reference)
      7–10 mm 1.05 (0.13–8.26) 0.962
      Pathology (%) Adenoma (reference)
      SSL 1.68 (0.45–6.26) 0.443
      Iatrogenic ulcer size ≤ 8 mm (reference)
      > 8 mm 3.89 (1.15–13.21) 0.029
      Table 1. Summary of Snare Characteristics

      Table 2. Baseline Characteristics

      Values are presented as number (%) unless otherwise indicated.

      SD, standard deviation; SSA/P, sessile serrated adenoma/polyp.

      Table 3. Comparison of Technical Factors and Adverse Events

      Values are presented as number (%).

      Table 4. Comparison of Complete and Incomplete Resection between the 2 Groups

      Values are presented as % (number/number).

      SSL, sessile serrated lesion; MM, muscularis mucosa; SM, submucosa.

      Table 5. Logistic Regression Analysis of Complete Resection Rate

      OR, odds ratio; CI, confidence interval; SSL, sessile serrated lesion.


      Intest Res : Intestinal Research
      Close layer
      TOP